meili 发表于 2022-10-27 14:53:49

kic2023炉温测试仪从炉子里出来读不出数据怎么办?

<p>问题:kic2023炉温测试仪从炉子里出来读不出数据怎么办?
<p>答案:↓↓↓<p class="nav-title mt10" style="border-top:1px solid #ccc;padding-top: 10px;">康欣的回答:<div class="content-b">网友采纳  通常是仪器过热自动保护后怎样进行复位?  退出KIC2000软件  1,找到KICProfiler2000Logkic2000usersettings.kiccfg,用记事本方式打开  2,把文件中的ViewHostDialog=0改为=1,然后保存并退出.  再次启动KIC2000软件你就可以看到KICHost界面了.  Cantrythesesteps,remarktousingEnglishLanguage  Recommendisuse9VALKALINEBattery  1.x09MakesuretheSlinKIC2000softwareisclose.  2.x09Undertherootdirectoryonyourharddrive,underthefoldertheKICProfiler2000youwillfindafoldercalled"Log".(UsingWindowsExplorer,opentheX:KICProfiler2000Logkic2000usersettings.kiccfgfile)  3.x09UndertheLogfolderthereisafilecalled"KIC2000UserSettings.KICCFG"  4.x09OpenthisfileusingNoteorWordPadtexteditor.  5.x09Withfileopenedunderthetexteditor,findtheline:("ViewHostDialog=0",Setthislineto=1,Savechangestothefile.)  6.x09RestarttheSlimKIC2000softwareandyoumoticethatasecondapplicationwillopen,theKICHost.(OntheWindowsTaskbar,clickonthe"KICHost"tab)  7.x09DirectconnectiontoSlimKIC2000,restartSlimKIC2000Unit.  8.x09Select"ConfigureSlimKIC".  9.x09AnotherWindowwillopen.Select"WriteSlimKICSetuop".Youshouldseedialogappearinthatwindowwhichsays"WriteSlimKICSuccessful".  由深圳市时汉电子为你专业服务,如有不明白的地方.CALL:13802708085唐/R